3D Laser Scanning · 2D Floor Plans · Historic Buildings

Existing-Conditions Documentation for Two Historic Buildings

Architectural layout of a building.
BUILDINGS CAPTURED
Two buildings
PRIMARY BUILDING
Three floors plus basement
SECONDARY BUILDING
Two levels, mezzanine, ballroom, and 16 rooms
DELIVERABLES
Floor-plan DWGs and point cloud; no STEP file and no 3D model
ACCURACY REQUIREMENT
1/2 inch
QA/QC
Cintoo QC
PROJECT OVERVIEW

The Project Need

The owner needed existing-condition information for two buildings as a basis for remodeling plans. OAR documented the interior spaces and delivered 2D floor-plan information together with point-cloud data.

OAR'S SCOPE

Interior documentation, floor-plan DWGs, point-cloud delivery, and Cintoo QC

OAR documented two buildings with floor-plan DWGs and point-cloud data that the owner used as a basis for remodeling and redesign work.

OAR'S SCOPE

Document the interiors. Deliver practical 2D plans and point-cloud data.

01

Interior Documentation

TWO BUILDINGS · INTERIOR SPACES · EXTERIOR EXCLUDED

OAR captured the listed interior spaces across two buildings. Exterior areas were excluded.

02

DWG Deliverables

FLOOR PLANS · GENERAL DIMENSIONS · WINDOW-SILL ELEVATIONS

The DWG package contained floor plans with general dimensions and window-sill elevations.

03

Point-Cloud Delivery

POINT CLOUD + FLOOR PLANS

A point cloud was delivered with the floor plans.

04

Accuracy and QC

1/2 INCH · CINTOO QC

The required accuracy was 1/2 inch, with Cintoo used for point cloud vs model for QA.

PROJECT OUTCOME

How the Deliverable Was Used

The client used the floor plans and point cloud as the basis for its own remodeling and redesign work. OAR did not perform the design, drapery, or installation work.

Project Outcome
The project provided the owner with documented interior conditions for two buildings in a floor-plan and point-cloud workflow. The property was unoccupied during the fieldwork.

What Was Included

Primary building: three floors plus basement

Secondary building: two levels and a mezzanine

Ballroom

16 rooms in the secondary building

Floor plans with general dimensions

Window-sill elevations

Point cloud

1/2 inch accuracy requirement

Cintoo QC

Project Visuals
PROJECT CONTEXT

What This Workflow Demonstrates

This project demonstrates how 2D drawings and point-cloud data can work together when an owner needs a practical existing-conditions reference without requiring a full 3D model.

Related OAR Services
3D Laser Scanning→
Existing Conditions Documentation→
Digital Delivery & Implementation→

Related projects
Cluttered interior with colorful materials.

BIM Coordination Framework for a Greenfield Recycling Facility

VIEW PROJECT →
Industrial space with pipes and equipment

LOD 350 Existing-Conditions and MEP Interference Modeling for a Chiller Replacement Inside an Operational School

VIEW PROJECT →
Industrial space with exposed structure

LOD 300 Existing-Conditions Modeling for a 44,600 SF Tenant Conversion

VIEW PROJECT →

Need existing-condition documentation without a full 3D model?

OAR can tailor the deliverable to the project, from point-cloud data and 2D floor plans to more detailed modeled workflows when required.